Buy PTFE Liners Online!
news banner

update

Everything You Need to Know About Steerable Guiding Sheath

Everything You Need to Know About Steerable Guiding Sheath

25 February 21

All About a Steerable Guiding Sheath

A steerable guiding sheath usually involves a dilator, guidewire, and a steerable sheath.  Their very specific design eases the way for a catheter whenever the need arises for cardio muscular anatomy. A steerable guiding sheath usually minimizes the blood loss induced by a catheter.  Blood loss is a major symptom or byproduct during the exchange of catheters. Excessive blood loss can result in severe conditions.

Moreover, the steerable guiding sheath comes with an inbuilt three-valve stopcock which helps in getting blood specimen, liquid distillation and observing pressure throughout the procedure.  The handle that introduces the guiding sheath can rotate clockwise and anticlockwise depending on the refraction and its flexibility.

steerable guiding sheath

The major purpose behind using a steerable sheath is to minimize the occurrence of cavities and air pockets.  Plus, it enables a clear visualization with the help of marker tips that come lubricated to ensure easy passage. It is common for the exterior and interior to come in pre-lubricated packaging. The dilator design imitates the diameter of the sheath from within such that it narrows down as it proceeds towards the tip.

Why use a Steerable Guiding Sheath?

The use of steerable guiding sheath is much preferred when introducing different kinds of catheters especially in procedures that involve cardiovascular muscles. We already know that procedures related to the heart are quite complex and required extreme skills and diligence.

Using a steerable sheath makes the operation related to the heart much easier.  The contents including the sheath packaging are sterile in nature. It is necessary to dispose of the sheath if you get a damaged packaging broken from the outside.

Things to Consider

Another important factor is that you can use the guiding sheath only once and that too for a single patient.  It is dangerous to use the same sheath again due to the possibility of infection contamination.  If you reuse it, you might compromise its physical reliability. This can also lead to failed results in patients causing severe illness or even death. We cannot elaborate enough on the proper handling and usage of a steerable guiding sheath because it involves extreme care when dealing with procedures related to the heart.

Using a defective guiding sheath can lead to transmission and contamination with infections and bacteria.  Moreover, the device used is only recommended for trained professionals with a specialized license in performing cardiovascular surgeries.

How to use a Steerable Guiding Sheath

The reason to use a guiding sheath is that it allows ease in reaching the difficult parts when performing heart surgery. Moreover, this is why it is becoming a popular option for different kinds of surgeries.

It has successfully become a part of interventional radiology. What happens during interventional radiology is that sometimes during the procedure the operator might face unknown facets.

There might be times when the surgery might not go according to the plan and the operator comes face to face with a target that was not included in the initial exam. Thus, with the availability of already available catheterization equipment precision is not possible. Steerable guiding sheath helps in achieving exactly that precision that operators want when performing complex procedures.

A step-by-step guide to using Steerable Guiding Sheath

Since, any kind of surgery involves precision, skill, and attention, a steerable sheet can help you achieve all these.  Whenever performing any endovascular renal denervation, the standard is to make a puncture in the artery as a standard femoral.  This helps in making way for a dilator that can have a 7 to 8 French standard measurement.  Then the operator needs to insert the sheath along with its dilator.

The tip of the sheath helps in achieving the desired level so that the dilator can easily be removed. For this procedure, a very standard type of guiding wire helps in keeping the tip inside the edge. When the sheath flushes, it helps in rotating the cursor which further helps in achieving the desired curve.

With the help of using a contrast medium injection, the operator can easily view the originating of the renal arteries.  Then the operator needs to pull down the sheath with very gentle movements. They need to keep on repeating this until the vessel engages so that they can easily perform the angiography.

As soon as the operator gets the vessel sizes, the electrode inserts through the sheath by using fluoroscopy.  All the while insulation takes place through the artery.  The latter procedure helps in releasing the curve of the guiding sheath which prevents the dislodging from the artery. On the other hand, the same procedure takes place from the other side too.  Later when the sheath has formed its prime functionality the operator takes it out and the closure for the artery happens to end the procedure.

Companies Providing Best Steerable Guiding Sheaths

Many companies have different variations of steerable guiding sheaths. All are providing quality products regarding catheters and guiding sheaths. https://www.enoveoem.com/ is one of the leading brands that are producing quality steerable guiding sheets.

The guiding sheaths they are manufacturing have an outer layer of Pebax. The middle layer consists of stainless flat steel or round wires. Whereas, the inner layer is of Ptfe Liner or Pebax.

The key features include an ergonomic grip that has vibrant stamping to highlight the curve. This also shows the curve refraction, the French size, and the length of the guiding sheath. The position of the tip points towards the decamped curve showing impartiality to any specific organ.  With penetration patterns, they help in easy documentation and locating specific organs using the sheath.

Moreover, the dilated cap has a french size and a guidewire indicator.  This also helps in reducing blood loss.

Product Specification

The product specification includes the length of 8 to 14 French that can reach up to 800 to 1200 mm. The bending ability has an angle between 90 to 180 degrees.  They also provide the facility of designing the sheath according to the specified requirements as well.  You can also achieve different shapes which help in achieving variety like spring type and braided type for achieving one way, two way, three-way, and four-way shapes.

The product packaging includes individual pouches for hygienic and infection-less products. You can also ask for the hydrophilic coating to further decreases the chances of transmission of infections and bacteria.

There are many other brands that are producing quality and desirable products like steerable guiding sheaths, dilators, and catheters. It can get daunting choosing the right company. So before you choose one, you must go through the product configuration, specification, description, and brand name. The sensitivity of the matter depends highly on the quality of the product.

steerable guiding sheath

Summary

Nowadays, it is important for the operators to use steerable guiding sheaths whenever performing cardiovascular and basically any kind of surgery that requires precision. The earlier version of guiding sheaths was not very precise hence the results were quite vague.  Moreover, it is important to know the procedure involving the use of a guiding sheath properly.

All the procedures that involve a guiding sheath must take place under a specialized operator that knows how to perform surgery using these tools and modern equipment. We should be thankful for the new technology because it has enabled the operators in getting precise results.  The flexibility of the steerable sheath can help reach parts that were not reachable earlier. Hence, modern technology is a viable option when performing complex procedures.

For More Information, Contact Us Today!